Cat No
Output Rating KvA
Output Rating Kw
Power Factor
Serial Communication
Protection Degree
Operating Temp. (Ambient)
Standard
Ventilation
Altitude
Relative Humidity
Acoustic Noise at 1m
Voltage/Tolerance
Bypass Voltage
Input Frequency
Maximum RFI
Output Voltage
Voltage Stability
Voltage Recovery Time
Frequency
Frequency Tolerance
Efficiency at 100% Load
Crest Factor
Short Circuit Protection
Overload Capacity
Total Harmonic Distortion
Battery Type
Number of 12V Blocks
Float Charging Value
End of Discharge Voltage
Battery Charging Characteristics
Battery Ambient Temperature
Automatic Battery Test
Battery Protection
Dimensions W x D x H (mm)
Weight (Kg)
|
HPAC4
4
3.2
0.8
Dry contacts plus RS232
IP41
0-40°C
Emergency lighting EN50171
Forced air cooling
<1000 Metres (above sea level)
90% maximum (non-condensing)
<56 dBA
230Vac single phase, 4 wires + ground / ± 15%
230Vac single phase
50Hz ± 5% (60Hz to order)
EN 50091-2 class A
230Vac single phase
Static (balanced load) ± 1%
Static (unbalanced load) ± 2%
Dynamic (step load 0-100%) ± 5%
After step load 0-100% maximum 20ms
50Hz (60Hz to order)
Line synchronised ± 1%
Free running ± 0.2%
>87-91%
3:1
Electronic short circuit
120% continuous, 150% load 10 minutes, 180% load 1 minute, 200% load for 1 second
Linear load <3%
Non-linear load 75% NP and CF 3:1) <5%
Sealed lead acid - maintenance free
16
216Vdc
160Vdc
Electronic short circuit
25°C
Weekly
Circuit breaker
300 x 500 x 1220
85
|
Cat No
Output Rating KvA
Output Rating Kw
Power Factor
Serial Communication
Protection Degree
Operating Temp. (Ambient)
Standard
Ventilation
Altitude
Relative Humidity
Acoustic Noise at 1m
Voltage/Tolerance
Bypass Voltage
Input Frequency
Maximum RFI
Output Voltage
Voltage Stability
Voltage Recovery Time
Frequency
Frequency Tolerance
Efficiency at 100% Load
Crest Factor
Short Circuit Protection
Overload Capacity
Total Harmonic Distortion
Battery Type
Number of 12V Blocks
Float Charging Value
End of Discharge Voltage
Battery Charging Characteristics
Battery Ambient Temperature
Automatic Battery Test
Battery Protection
Dimensions W x D x H (mm)
Weight (Kg)
|
HPAC5
5
4
0.8
Dry contacts plus RS232
IP41
0-40°C
Emergency lighting EN50171
Forced air cooling
<1000 Metres (above sea level)
90% maximum (non-condensing)
<56 dBA
230Vac single phase, 4 wires + ground / ± 15%
230Vac single phase
50Hz ± 5% (60Hz to order)
EN 50091-2 class A
230Vac single phase
Static (balanced load) ± 1%
Static (unbalanced load) ± 2%
Dynamic (step load 0-100%) ± 5%
After step load 0-100% maximum 20ms
50Hz (60Hz to order)
Line synchronised ± 1%
Free running ± 0.2%
>87-91%
3:1
Electronic short circuit
120% continuous, 150% load 10 minutes, 180% load 1 minute, 200% load for 1 second
Linear load <3%
Non-linear load 75% NP and CF 3:1) <5%
Sealed lead acid - maintenance free
18
243Vdc
180Vdc
Electronic short circuit
25°C
Weekly
Circuit breaker
300 x 500 x 1220
95
|
Cat No
Output Rating KvA
Output Rating Kw
Power Factor
Serial Communication
Protection Degree
Operating Temp. (Ambient)
Standard
Ventilation
Altitude
Relative Humidity
Acoustic Noise at 1m
Voltage/Tolerance
Bypass Voltage
Input Frequency
Maximum RFI
Output Voltage
Voltage Stability
Voltage Recovery Time
Frequency
Frequency Tolerance
Efficiency at 100% Load
Crest Factor
Short Circuit Protection
Overload Capacity
Total Harmonic Distortion
Battery Type
Number of 12V Blocks
Float Charging Value
End of Discharge Voltage
Battery Charging Characteristics
Battery Ambient Temperature
Automatic Battery Test
Battery Protection
Dimensions W x D x H (mm)
Weight (Kg)
|
HPAC6
6
4.8
0.8
Dry contacts plus RS232
IP41
0-40°C
Emergency lighting EN50171
Forced air cooling
<1000 Metres (above sea level)
90% maximum (non-condensing)
<56 dBA
230Vac single phase, 4 wires + ground / ± 15%
230Vac single phase
50Hz ± 5% (60Hz to order)
EN 50091-2 class A
230Vac single phase
Static (balanced load) ± 1%
Static (unbalanced load) ± 2%
Dynamic (step load 0-100%) ± 5%
After step load 0-100% maximum 20ms
50Hz (60Hz to order)
Line synchronised ± 1%
Free running ± 0.2%
>87-91%
3:1
Electronic short circuit
120% continuous, 150% load 10 minutes, 180% load 1 minute, 200% load for 1 second
Linear load <3%
Non-linear load 75% NP and CF 3:1) <5%
Sealed lead acid - maintenance free
18
243Vdc
180Vdc
Electronic short circuit
25°C
Weekly
Circuit breaker
300 x 500 x 1220
110
|
Cat No
Output Rating KvA
Output Rating Kw
Power Factor
Serial Communication
Protection Degree
Operating Temp. (Ambient)
Standard
Ventilation
Altitude
Relative Humidity
Acoustic Noise at 1m
Voltage/Tolerance
Bypass Voltage
Input Frequency
Maximum RFI
Output Voltage
Voltage Stability
Voltage Recovery Time
Frequency
Frequency Tolerance
Efficiency at 100% Load
Crest Factor
Short Circuit Protection
Overload Capacity
Total Harmonic Distortion
Battery Type
Number of 12V Blocks
Float Charging Value
End of Discharge Voltage
Battery Charging Characteristics
Battery Ambient Temperature
Automatic Battery Test
Battery Protection
Dimensions W x D x H (mm)
Weight (Kg)
|
HPAC8
8
6.4
0.8
Dry contacts plus RS232
IP41
0-40°C
Emergency lighting EN50171
Forced air cooling
<1000 Metres (above sea level)
90% maximum (non-condensing)
<56 dBA
230Vac single phase, 4 wires + ground / ± 15%
230Vac single phase
50Hz ± 5% (60Hz to order)
EN 50091-2 class A
230Vac single phase
Static (balanced load) ± 1%
Static (unbalanced load) ± 2%
Dynamic (step load 0-100%) ± 5%
After step load 0-100% maximum 20ms
50Hz (60Hz to order)
Line synchronised ± 1%
Free running ± 0.2%
>87-91%
3:1
Electronic short circuit
120% continuous, 150% load 10 minutes, 180% load 1 minute, 200% load for 1 second
Linear load <3%
Non-linear load 75% NP and CF 3:1) <5%
Sealed lead acid - maintenance free
20
270Vdc
200Vdc
Electronic short circuit
25°C
Weekly
Circuit breaker
300 x 500 x 1220
125
|
Cat No
Output Rating KvA
Output Rating Kw
Power Factor
Serial Communication
Protection Degree
Operating Temp. (Ambient)
Standard
Ventilation
Altitude
Relative Humidity
Acoustic Noise at 1m
Voltage/Tolerance
Bypass Voltage
Input Frequency
Maximum RFI
Output Voltage
Voltage Stability
Voltage Recovery Time
Frequency
Frequency Tolerance
Efficiency at 100% Load
Crest Factor
Short Circuit Protection
Overload Capacity
Total Harmonic Distortion
Battery Type
Number of 12V Blocks
Float Charging Value
End of Discharge Voltage
Battery Charging Characteristics
Battery Ambient Temperature
Automatic Battery Test
Battery Protection
Dimensions W x D x H (mm)
Weight (Kg)
|
HPAC12
12.5
10
0.8
Dry contacts plus RS232
IP41
0-40°C
Emergency lighting EN50171
Forced air cooling
<1000 Metres (above sea level)
90% maximum (non-condensing)
<56 dBA
230Vac single phase, 4 wires + ground / ± 15%
230Vac single phase
50Hz ± 5% (60Hz to order)
EN 50091-2 class A
230Vac single phase
Static (balanced load) ± 1%
Static (unbalanced load) ± 2%
Dynamic (step load 0-100%) ± 5%
After step load 0-100% maximum 20ms
50Hz (60Hz to order)
Line synchronised ± 1%
Free running ± 0.2%
>87-91%
3:1
Electronic short circuit
120% continuous, 150% load 10 minutes, 180% load 1 minute, 200% load for 1 second
Linear load <3%
Non-linear load 75% NP and CF 3:1) <5%
Sealed lead acid - maintenance free
20
270Vdc
200Vdc
Electronic short circuit
25°C
Weekly
Circuit breaker
300 x 500 x 1220
155
|
Cat No
Output Rating KvA
Output Rating Kw
Power Factor
Serial Communication
Protection Degree
Operating Temp. (Ambient)
Standard
Ventilation
Altitude
Relative Humidity
Acoustic Noise at 1m
Voltage/Tolerance
Bypass Voltage
Input Frequency
Maximum RFI
Output Voltage
Voltage Stability
Voltage Recovery Time
Frequency
Frequency Tolerance
Efficiency at 100% Load
Crest Factor
Short Circuit Protection
Overload Capacity
Total Harmonic Distortion
Battery Type
Number of 12V Blocks
Float Charging Value
End of Discharge Voltage
Battery Charging Characteristics
Battery Ambient Temperature
Automatic Battery Test
Battery Protection
Dimensions W x D x H (mm)
Weight (Kg)
|
HPAC20/SP
20
14
0.8
Dry contacts plus RS232
IP41
0-40°C
Emergency lighting EN50171
Forced air cooling
<1000 Metres (above sea level)
90% maximum (non-condensing)
<56 dBA
230Vac single phase, 4 wires + ground / ± 15%
230Vac single phase
50Hz ± 5% (60Hz to order)
EN 50091-2 class A
230Vac single phase
Static (balanced load) ± 1%
Static (unbalanced load) ± 2%
Dynamic (step load 0-100%) ± 5%
After step load 0-100% maximum 20ms
50Hz (60Hz to order)
Line synchronised ± 1%
Free running ± 0.2%
>87-91%
3:1
Electronic short circuit
120% continuous, 150% load 10 minutes, 180% load 1 minute, 200% load for 1 second
Linear load <3%
Non-linear load 75% NP and CF 3:1) <5%
Sealed lead acid - maintenance free
26
354Vdc
260Vdc
Electronic short circuit
25°C
Weekly
Circuit breaker
TBC
TBC
|