Ancillary Equipment

A range of essential fire alarm system equipment

Ancillary Equipment

A range of essential fire alarm system equipment

Key Features

  • A comprehensive range of products to provide practical and reliable solutions to most fire alarm systems
  • FP-016 and FPA-674 are designed to operate external equipment such as door retainers, roller-shutter doors, air-conditioning systems and plant shutdown equipment
  • FPA-014 and FPA-662 provide indication of detectors that are concealed within relatively inaccessible areas
  • FPA-198 and FPA-199 are suitable for use with autodiallers, water sprinklers and roller-shutters
  • FPA-304 auto-dialler is suitable for use with conventional, two-wire and addressable fire alarm systems
  • FPA-311 and FPA-312 are suitable for the disablement of existing circuits, zones and sounder circuits
  • FPA-547 is suitable for use with all conventional, two-wire and addressable fire alarm panels (including repeater panels)
  • FPA-593 and FPA-594 are suitable for use in hotel bedrroms and care homes
  • FPA-648 meets the test record requirements of BS5839
  • FPA-712 provides a lockable durable solution for essential on-site equipment, documents and log books
Cat No Description Function
FP-016 Fire Output Relay Incorporates a red LED which illuminates when the relay is active.  The fire output relay is connected to a control panel relay output or a standard polarised fire alarm sounder circuit to operate door retaining magnets and rollershutter doors.
FPA-014 Remote Detector Indicator Incorporates a red LED that is clearly visible when active.  The remote detector indicator’s primary use is to indicate the activation of an out-of-sight smoke or heat detector.
FPA-198 Keyswitch Auxiliary Device Isolator Allows a +24V d.c. output from a fire panel to be remotely isolated to prevent external equipment such as autodiallers and rollershutter doors from operating. This is a particularly useful function during routine maintenance as it safeguards against the inadvertent triggering of auxiliary equipment. The unit incorporates an isolating keyswitch and amber LED.
FPA-199 24V 5A Keyswitch with Buzzer Combines the functions of the FP-016 relay and FPA-198 device isolator in one unit. It is a double-pole 24V 5A polarised relay with a keyswitch isolation facility allowing its relay operation to be temporarily disabled from the fire alarm signal during routine test and maintenance, preventing autodiallers and water sprinklers from activating.
FPA-547 Mains Voltage Isolator Switch Provides a secure method of isolation for fire alarm mains supply Voltage in accordance with the recommendations of BS 5839 Pt1: 2017 25.2 for mains power supplies. The supply is isolated by means of a key switch and an LED indicates the supply of power.
FPA-648 Fire Alarm and Emergency Lighting Log Book Meets the test record requirements of BS5839 and the legal obligations under the Regulatory Reform Order. The log book includes sections to include details of the fire alarm system, service and activation details as well as staff training, drills, emergency lighting and much more.
FPA-712 Lockable Steel Document Enclosure A key lockable, robust steel enclosure for the safe storage of important documents such as the fire alarm panel user manuals and test log book. The enclosure has ample room to hold documents up to A4 size.
FPA-996 4 Zone Monitored Sounder Extender Provides four extra sounder circuits with open and short circuit fault monitoring. It is compatible with most fire alarm control panels and is supplied mounted on a double gang plate which fits standard UK 25mm-deep back boxes.

Cat No

Description

Function

FP-016
Fire Output Relay
Incorporates a red LED which illuminates when the relay is active.  The fire output relay is connected to a control panel relay output or a standard polarised fire alarm sounder circuit to operate door retaining magnets and rollershutter doors.

Cat No

Description

Function

FPA-014
Remote Detector Indicator
Incorporates a red LED that is clearly visible when active.  The remote detector indicator’s primary use is to indicate the activation of an out-of-sight smoke or heat detector.

Cat No

Description

Function

FPA-198
Keyswitch Auxiliary Device Isolator
Allows a +24V d.c. output from a fire panel to be remotely isolated to prevent external equipment such as autodiallers and rollershutter doors from operating. This is a particularly useful function during routine maintenance as it safeguards against the inadvertent triggering of auxiliary equipment. The unit incorporates an isolating keyswitch and amber LED.

Cat No

Description

Function

FPA-199
24V 5A Keyswitch with Buzzer
Combines the functions of the FP-016 relay and FPA-198 device isolator in one unit. It is a double-pole 24V 5A polarised relay with a keyswitch isolation facility allowing its relay operation to be temporarily disabled from the fire alarm signal during routine test and maintenance, preventing autodiallers and water sprinklers from activating.

Cat No

Description

Function

FPA-547
Mains Voltage Isolator Switch
Provides a secure method of isolation for fire alarm mains supply Voltage in accordance with the recommendations of BS 5839 Pt1: 2017 25.2 for mains power supplies. The supply is isolated by means of a key switch and an LED indicates the supply of power.

Cat No

Description

Function

FPA-648
Fire Alarm and Emergency Lighting Log Book
Meets the test record requirements of BS5839 and the legal obligations under the Regulatory Reform Order. The log book includes sections to include details of the fire alarm system, service and activation details as well as staff training, drills, emergency lighting and much more.

Cat No

Description

Function

FPA-712
Lockable Steel Document Enclosure
A key lockable, robust steel enclosure for the safe storage of important documents such as the fire alarm panel user manuals and test log book. The enclosure has ample room to hold documents up to A4 size.

Cat No

Description

Function

FPA-996
4 Zone Monitored Sounder Extender
Provides four extra sounder circuits with open and short circuit fault monitoring. It is compatible with most fire alarm control panels and is supplied mounted on a double gang plate which fits standard UK 25mm-deep back boxes.