2, 4 & 8-zone fire alarm panels with LCD display

Twin-Flex Pro Fire Alarm Panels

2, 4 & 8-zone fire alarm panels with LCD display

Key Features

  • Available in 2, 4 and 8 zone versions
  • 4 line x 20 character LC D display
  • Ability to differentiate between call-point or detector alarms
  • Checkpoint alarm verification feature
  • Highlighted selection menu
  • Event log storing up to 500 events
  • 3 enhanced test modes
  • Allows detectors and sounders to be installed on the same pair of wires
  • Up to 32 devices per zone
  • Built-in end-of-line capability in all devices
  • 7 modes of detection (3 forms of smoke detection, 3 forms of heat detection and 1 combined smoke and heat detection)
  • Handy contractor kits available; consisting of a panel, 6 Multipoints, 2 call points and a head removal tool
  • 1 to 5 minute variable time alarm delay feature enabling investigation of the cause of activation, thus eliminating false alarms

Fire Alarm Panel

Fire Alarm Panel

Cat No Description Max Battery Type & Size
FPA-198 1 Gang Keyswitch Auxiliary Device Isolator -
FPA-199 24V 5A Keyswitch with Buzzer -
FPA-226 Network Driver Card (1 Required Per System) -
FPA-227 Relay Output Card (Provides Reset, Fault Aux Fire and Remote Relay Outputs) -
FPA-228 Relay Output Card (as Per FPA-227 Plus 8 Output Per Zone Relays) -
FPA-260 Spare Red Key for CFP/XFP Fire Alarm Panels -
FPA-304 Short message communicator (for signalling alarm and other system conditions by sending a SMS text message to the user) -
FPA-595 Spares pack including 8 x 0.47 µF 50V capacitors, 4 x 6K8 0.25W resistors, 1 x mains fuse, 1 x battery connection kit, 2 x nylon cable ties (for securing the batteries into the panel enclosure) and 1 x LPCB approval label -
FPA-996 4 Zone Monitored Sounder Extender 2 Gang -

Cat No

Description

Max Battery Type & Size

FPA-198
1 Gang Keyswitch Auxiliary Device Isolator
-

Cat No

Description

Max Battery Type & Size

FPA-199
24V 5A Keyswitch with Buzzer
-

Cat No

Description

Max Battery Type & Size

FPA-226
Network Driver Card (1 Required Per System)
-

Cat No

Description

Max Battery Type & Size

FPA-227
Relay Output Card (Provides Reset, Fault Aux Fire and Remote Relay Outputs)
-

Cat No

Description

Max Battery Type & Size

FPA-228
Relay Output Card (as Per FPA-227 Plus 8 Output Per Zone Relays)
-

Cat No

Description

Max Battery Type & Size

FPA-260
Spare Red Key for CFP/XFP Fire Alarm Panels
-

Cat No

Description

Max Battery Type & Size

FPA-304
Short message communicator (for signalling alarm and other system conditions by sending a SMS text message to the user)
-

Cat No

Description

Max Battery Type & Size

FPA-595
Spares pack including 8 x 0.47 µF 50V capacitors, 4 x 6K8 0.25W resistors, 1 x mains fuse, 1 x battery connection kit, 2 x nylon cable ties (for securing the batteries into the panel enclosure) and 1 x LPCB approval label
-

Cat No

Description

Max Battery Type & Size

FPA-996
4 Zone Monitored Sounder Extender 2 Gang
-
Cat No Description
FP-041 2 zone two-wire panel
FP-042 4 zone two-wire panel
FP-043 8 zone two-wire panel

Cat No

Description

FP-041
2 zone two-wire panel

Cat No

Description

FP-042
4 zone two-wire panel

Cat No

Description

FP-043
8 zone two-wire panel
Control Panels:
Width 331mm x Height 331mm x Depth 99mm

Repeater Panels:
Width 250mm x Height 140mm x Depth 85mm

Specification / Technical Information

  • Construction - V2 rated ABS
  • Ingress Rating - IP30
  • Repeater panel is not suitable for use with 2 zone control panels
  • Batteries to be ordered separately
  • A separate PSU can be used to power repeaters
  • Contractor kits include 1 x panel, 6 x Multipoints c/w Sounder, 1 x Multipoint c/w Sounder and Strobe, 2 x call points and 1 x detector head removal tool

Quick Enquiry

or call us on +44 (0) 1922 745024