CFP Two-Wire Fire Alarm Panels
EN54-2 & 4-compliant, intuitive and user-friendly two-wire fire alarm panels
Key Features
- Designed to comply with EN54 Parts 2 and 4
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
- Available with 2, 4 or 8 AlarmSense zone circuits (dependent on model purchased)
- 4 conventional sounder circuits (for use with non-AlarmSense sounders)
- Integral 1.5A EN54-4/A2 compliant switch mode PSU
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones
- 2 on-board relays (fire and fault)
- 2 open-collector outputs (remote and reset)
- ‘Class change’ and alert inputs
- Installer friendly design accommodates easy first fix and straight forward maintenance
- Low quiescent current
- Multiple indicators
- End of line units included (one per zone)
- Ancillary system expansion connections provided for up to 8 two-wire repeaters (1 FPA -226 network driver card required per system) and optional relay card
- Space for 2 x 12V 2.1Ah or 3.2Ah VRLA batteries
- Attractive flush or surface mountable plastic lid and enclosure (no bezel required)
- Third party LPCB tested
Fire Alarm Panel
Fire Alarm Panel
Cat No |
Description |
Max Battery Type & Size |
FP-041 |
2 zone two-wire panel |
2 x 3.2Ah (FPA-071) |
FP-042 |
4 zone two-wire panel |
2 x 3.2Ah (FPA-071) |
FP-043 |
8 zone two-wire panel |
2 x 3.2Ah (FPA-071) |
Cat No
Description
Max Battery Type & Size
|
FP-041
2 zone two-wire panel
2 x 3.2Ah (FPA-071)
|
Cat No
Description
Max Battery Type & Size
|
FP-042
4 zone two-wire panel
2 x 3.2Ah (FPA-071)
|
Cat No
Description
Max Battery Type & Size
|
FP-043
8 zone two-wire panel
2 x 3.2Ah (FPA-071)
|
Repeater Panel
Repeater Panel
Cat No |
Description |
Max Battery Type & Size |
FPR-006 |
8 zone repeater panel |
2 x 3.2Ah (FPA-071) |
Cat No
Description
Max Battery Type & Size
|
FPR-006
8 zone repeater panel
2 x 3.2Ah (FPA-071)
|
|
Cat No |
Description |
 |
FPA-198 |
1 Gang Keyswitch Auxiliary Device Isolator |
 |
FPA-199 |
24V 5A Keyswitch with Buzzer |
 |
FPA-226 |
Network Driver Card (1 Required Per System) |
 |
FPA-227 |
Relay Output Card (Provides Reset, Fault Aux Fire and Remote Relay Outputs) |
 |
FPA-228 |
Relay Output Card (as Per FPA-227 Plus 8 Output Per Zone Relays) |
 |
FPA-260 |
Spare Red Key for CFP/XFP Fire Alarm Panels |
 |
FPA-996 |
4 Zone Monitored Sounder Extender 2 Gang |
|
Cat No
Description
|
FPA-198
1 Gang Keyswitch Auxiliary Device Isolator
|
|
Cat No
Description
|
FPA-199
24V 5A Keyswitch with Buzzer
|
|
Cat No
Description
|
FPA-226
Network Driver Card (1 Required Per System)
|
|
Cat No
Description
|
FPA-227
Relay Output Card (Provides Reset, Fault Aux Fire and Remote Relay Outputs)
|
|
Cat No
Description
|
FPA-228
Relay Output Card (as Per FPA-227 Plus 8 Output Per Zone Relays)
|
|
Cat No
Description
|
FPA-260
Spare Red Key for CFP/XFP Fire Alarm Panels
|
|
Cat No
Description
|
FPA-996
4 Zone Monitored Sounder Extender 2 Gang
|
Dimensions
Width 380mm x Height 235mm x Depth 96mm
Weight
1.75Kg (without batteries)
Specification / Technical Information
- Construction - RAL 7035 textured plastic lid and base
- Ingress Rating - IP30
- All fire alarm panels have 4 sounder circuits
- Batteries to be ordered separately
- Maximum of 8 repeater panels per system (network card required at main panel)
- Repeater panel is only suitable for use with standard panels and cannot be used with economy panels