Key Features

  • Multiple call levels including standard, ensuite, help required, emergency, attack, presence & attendance
  • Wide range of system components including programmable call points, ceiling pulls, monitoring points, displays, infrared ceiling receivers, radio receivers, staff attack transmitters and neck pendants, overdoor lights and sounders
  • Flexible call routing; system can be tailored to suit a site’s exact operational requirements, whatever they may be
  • Call accept feature saves valuable time by preventing more than one member of staff responding to the same call
  • Automatic call divert transfers any unanswered calls to other areas to ensure they are responded to within a predetermined time
  • Follow-me lights illuminate overdoor lights and corridor lights in sequence to visually guide staff to the source of a call
  • Staff presence helps managers, matrons and carers locate their colleagues by showing where they are working at any given time
  • Staff attendance allows staff entering rooms to log their ‘attendance’ via an infrared call point or ceiling receiver
  • Call follower sounders inform staff that other calls are waiting by sounding an optional soft tone in all occupied rooms
  • Night mode allows the system to work in a totally different way at night, providing for fewer staff and reduced sound levels
  • Infrared security transmitters can help protect staff against disturbed patients, intruders and aggressive visitors
  • Surveyor data analysis software allows managers to output custom reports to a desktop PC on data such as longest calls, busiest shifts, most visited rooms etc
  • Optional alphanumeric and tone-only paging facilities are available for carers on the move
  • Device monitoring constantly supervises all network devices and informs you of any problems, reducing maintenance time and costs
  • Laptop programmable system controller allows the system to adapt to your changing requirements without the need for expensive rewiring
  • Easy to install and expand
  • Universal programming devices allow optional third-party switch assemblies to be interfaced to the system for optional compliance with HTM 08-03
  • Tried, trusted & respected by large NHS trusts to renowned nursing home groups
Cat No Description
FPA-406 Recessing bezel to suit ONC-020 Controller
ONC-001 Slave Ceiling Pull Unit
ONC-002 Overdoor Light c/w Sounder
ONC-003 Call Point c/w Remote Socket & Button Reset
ONC-020 Call System Controller (requires 2 x 7Ah batteries)
ONC-021 Upload/Download Programming Software & Lead (Windows XP/Vista/7)
ONC-022 Corridor Display with Controls
Also available for use on conventional and dementia care call systems
ONC-023 Corridor Display without Controls
ONC-024 Slave Overdoor Light
Also available for use on conventional and dementia care call systems
ONC-025 Call Point c/w Remote Socket & Magnetic Reset
ONC-027 Call Point c/w Button Reset (Without Remote Socket)
ONC-028 Call Point c/w Magnetic Reset (Without Remote Socket)
ONC-029 Monitoring Point c/w Button Reset
ONC-030 Master Infrared Ceiling Receiver
ONC-031 Slave Infrared Ceiling Receiver
ONC-032 Mk2 (868MHz) Radio Receiver (Compatible with ONC-033 Transmitter Only)
ONC-033 Infrared/Radio Staff Attack Transmitter (Push/Pull for Attack)
Also available for use on conventional and dementia care call systems
ONC-034 Single Way Charging Unit to suit ONC-033 Transmitter
Also available for use on conventional call system
ONC-035 Ten Way Charging Unit to suit ONC-033 Transmitter
Also available for use on conventional call system
ONC-037 Surveyor Data Management Software c/w Wall Socket and Lead (Windows XP/Vista/7)
ONC-038 Network Splitter
ONC-080 Infrared/Radio Transmitter (Push for Call/Pull for Attack)
Also available for use on conventional call system
ONC-081 Zone Specific Relay Output Device
ONC-082 Extension Aerial to suit ONC-032
ONC-083 RF Integrity ‘Monitored Heartbeat’ Transmitter (at least 1 per ONC-032 required)
ONC-084 Infrared/Radio Patient Neck Pendant c/w Lanyard (Push for Call)
ONC-085 Infrared/Radio Patient Wrist Pendant c/w Wrist Strap (Push for Call)
ONC-086 Infrared/Radio Attendance Pendant c/w Lanyard (Push for Attendance)
ONC-090 Hand/Foot Pneumatic Pad (Requires ONC-091)
Also available for use on conventional call system
ONC-091 Remote Air Switch to suit ONC-090 (Connects to ONC-003, ONC-044 or ONC-046)
Also available for use on conventional call system
ONC-092 Portable Movement Detector (Connects to ONC-003, ONC-044 or ONC-046)
Also available for use on conventional call system
ONC-093 Double Remote Jack Socket (Allows 2 Ancillary Calling Devices to be Connected)
Also available for use on conventional call system
ONC-094 Floor Pressure Mat (Connects to ONC-003, ONC-044 or ONC-046)
ONC-096 Configurator Adaptor c/w Lead and Software
ONC-097 High Output 85dB Addressable Sounder
ONC-100 Call Point with Sounder, IR Receiver & Button reset with remote socket

Cat No

Description

FPA-406
Recessing bezel to suit ONC-020 Controller

Cat No

Description

ONC-001
Slave Ceiling Pull Unit

Cat No

Description

ONC-002
Overdoor Light c/w Sounder

Cat No

Description

ONC-003
Call Point c/w Remote Socket & Button Reset

Cat No

Description

ONC-020
Call System Controller (requires 2 x 7Ah batteries)

Cat No

Description

ONC-021
Upload/Download Programming Software & Lead (Windows XP/Vista/7)

Cat No

Description

ONC-022
Corridor Display with Controls
Also available for use on conventional and dementia care call systems

Cat No

Description

ONC-023
Corridor Display without Controls

Cat No

Description

ONC-024
Slave Overdoor Light
Also available for use on conventional and dementia care call systems

Cat No

Description

ONC-025
Call Point c/w Remote Socket & Magnetic Reset

Cat No

Description

ONC-027
Call Point c/w Button Reset (Without Remote Socket)

Cat No

Description

ONC-028
Call Point c/w Magnetic Reset (Without Remote Socket)

Cat No

Description

ONC-029
Monitoring Point c/w Button Reset

Cat No

Description

ONC-030
Master Infrared Ceiling Receiver

Cat No

Description

ONC-031
Slave Infrared Ceiling Receiver

Cat No

Description

ONC-032
Mk2 (868MHz) Radio Receiver (Compatible with ONC-033 Transmitter Only)

Cat No

Description

ONC-033
Infrared/Radio Staff Attack Transmitter (Push/Pull for Attack)
Also available for use on conventional and dementia care call systems

Cat No

Description

ONC-034
Single Way Charging Unit to suit ONC-033 Transmitter
Also available for use on conventional call system

Cat No

Description

ONC-035
Ten Way Charging Unit to suit ONC-033 Transmitter
Also available for use on conventional call system

Cat No

Description

ONC-037
Surveyor Data Management Software c/w Wall Socket and Lead (Windows XP/Vista/7)

Cat No

Description

ONC-038
Network Splitter

Cat No

Description

ONC-080
Infrared/Radio Transmitter (Push for Call/Pull for Attack)
Also available for use on conventional call system

Cat No

Description

ONC-081
Zone Specific Relay Output Device

Cat No

Description

ONC-082
Extension Aerial to suit ONC-032

Cat No

Description

ONC-083
RF Integrity ‘Monitored Heartbeat’ Transmitter (at least 1 per ONC-032 required)

Cat No

Description

ONC-084
Infrared/Radio Patient Neck Pendant c/w Lanyard (Push for Call)

Cat No

Description

ONC-085
Infrared/Radio Patient Wrist Pendant c/w Wrist Strap (Push for Call)

Cat No

Description

ONC-086
Infrared/Radio Attendance Pendant c/w Lanyard (Push for Attendance)

Cat No

Description

ONC-090
Hand/Foot Pneumatic Pad (Requires ONC-091)
Also available for use on conventional call system

Cat No

Description

ONC-091
Remote Air Switch to suit ONC-090 (Connects to ONC-003, ONC-044 or ONC-046)
Also available for use on conventional call system

Cat No

Description

ONC-092
Portable Movement Detector (Connects to ONC-003, ONC-044 or ONC-046)
Also available for use on conventional call system

Cat No

Description

ONC-093
Double Remote Jack Socket (Allows 2 Ancillary Calling Devices to be Connected)
Also available for use on conventional call system

Cat No

Description

ONC-094
Floor Pressure Mat (Connects to ONC-003, ONC-044 or ONC-046)

Cat No

Description

ONC-096
Configurator Adaptor c/w Lead and Software

Cat No

Description

ONC-097
High Output 85dB Addressable Sounder

Cat No

Description

ONC-100
Call Point with Sounder, IR Receiver & Button reset with remote socket
Addressable Call System Operation
This powerful yet easy to use addressable call system helps ensure vital communication throughout a building. In environments where efficiency is paramount, the system delivers, helping save staff time, minimising disturbance and improving the quality of patient, customer and/or employee care.
Recently updated to include a host of new features, the way the system operates can be tailored to suit a care facility’s specific requirements. For example, different day, night and call divert arrangements can be easily accommodated to meet the exact operational needs and precise layout of any building.

Choosing & Planning a System
The flexibility of the system, coupled with many other advanced features such as multiple call levels, free in-built datalogging, simple system reprogramming and full monitoring of all network devices, makes this addressable system the obvious choice for nursing homes, hospitals, health centres and many other private and public sector establishments.
Up to 255 addressable devices (and an even larger number of slave and ancillary devices) can be connected to the system. In practice, systems can range from having just a handful of addressable devices (for example, a building that requires communication facilities in its disabled persons toilet only) to systems with in excess of 200 devices such as buildings requiring nursecall and infrared staff protection facilities.
As all addressable devices are soft addressed, no consideration needs to be given to how they will interact until system programming. System wiring, however, must be made in a ‘spine’ and ‘limb’ configuration using one or more network splitters. A point also worth taking into consideration is that indicator panels should always be sited internally in a clean dry area which is readily accessible to staff.

Specification / Technical Information

In its simplest form, an addressable call system:
  • Allows the general public, a member of staff or a patient to call for assistance
  • Confirms that the call has got through
  • Makes sure the caller is visited
  • If required, allows extra or more urgent assistance to be summoned using an optional ‘emergency’ call facility
Using the wide variety of options available, the system can also:
  • Informs staff that someone is being attacked via an optional infrared ‘staff attack’ facility
  • Monitors storage cupboards, cash offices and stock rooms for unauthorised access
  • Monitors doorbells, telephones and machinery for activation or failure
  • Sends notification of calls to hand-held paging equipment

Quick Enquiry

or call us on +44 (0) 1922 745024

0/250 Characters