XP95® Addressable Devices

A selection of addressable devices compatible with a wide range of fire alarm panels

XP95® Addressable Devices

A selection of addressable devices compatible with a wide range of fire alarm panels

Key Features

  • Alarm flag for fast alarm reporting
  • Alarm address for fast location of alarm
  • XPERT card addressing
  • Electronics-free base
  • Easy installation
  • Elegant design
  • Insect resistant
Cat No Description Suitable Use Dimensions
FPA-263 XP95® 55°C fixed heat detector Dirty or smoky environments Ø100mm x 42mmH
FPA-264 XP95® 90°C fixed heat detector Dirty or smoky environments Ø100mm x 42mmH
FPA-265 XP95® combined optical smoke fixed heat multisensor Sensitive to a wide range of fires Ø100mm x 50mmH
FPA-266 XP95® optical smoke detector (smouldering fires) Bedrooms and escape routes Ø100mm x 42mmH
FPA-267 XP95® ionisation smoke detector (flaming fires) Rooms opening onto escape routes Ø100mm x 42mmH
FPA-268 XP95® standard base c/w XPERT card Compatible with all XP95® detectors Ø100mm x 8mmH
FPA-270 XP95® isolating base Detects short circuit faults on XP95® loops Ø100mm x 24mmH
FPA-489 XP95® optical smoke detector black finish (smouldering fires) Bedrooms and escape routes Ø100mm x 42mmH
FPA-490 Complete set of pre-addressed XP95® XPERT cards (126 quantity) Compatible with all XP95® detectors -
FPA-490/BLANK Blank XP95® XPERT card Compatible with all XP95® detectors -
FPA-491 XP95® standard base c/w XPERT card black finish Compatible with all XP95® detectors Ø100mm x 8mmH

Cat No

Description

Suitable Use

Dimensions

FPA-263
XP95® 55°C fixed heat detector
Dirty or smoky environments
Ø100mm x 42mmH

Cat No

Description

Suitable Use

Dimensions

FPA-264
XP95® 90°C fixed heat detector
Dirty or smoky environments
Ø100mm x 42mmH

Cat No

Description

Suitable Use

Dimensions

FPA-265
XP95® combined optical smoke fixed heat multisensor
Sensitive to a wide range of fires
Ø100mm x 50mmH

Cat No

Description

Suitable Use

Dimensions

FPA-266
XP95® optical smoke detector (smouldering fires)
Bedrooms and escape routes
Ø100mm x 42mmH

Cat No

Description

Suitable Use

Dimensions

FPA-267
XP95® ionisation smoke detector (flaming fires)
Rooms opening onto escape routes
Ø100mm x 42mmH

Cat No

Description

Suitable Use

Dimensions

FPA-268
XP95® standard base c/w XPERT card
Compatible with all XP95® detectors
Ø100mm x 8mmH

Cat No

Description

Suitable Use

Dimensions

FPA-270
XP95® isolating base
Detects short circuit faults on XP95® loops
Ø100mm x 24mmH

Cat No

Description

Suitable Use

Dimensions

FPA-489
XP95® optical smoke detector black finish (smouldering fires)
Bedrooms and escape routes
Ø100mm x 42mmH

Cat No

Description

Suitable Use

Dimensions

FPA-490
Complete set of pre-addressed XP95® XPERT cards (126 quantity)
Compatible with all XP95® detectors
-

Cat No

Description

Suitable Use

Dimensions

FPA-490/BLANK
Blank XP95® XPERT card
Compatible with all XP95® detectors
-

Cat No

Description

Suitable Use

Dimensions

FPA-491
XP95® standard base c/w XPERT card black finish
Compatible with all XP95® detectors
Ø100mm x 8mmH
Cat No Description Dimensions
FPA-081/4 Protective cover to suit FPA-269 and FPA-504 call points -
FPA-269 XP95® call point c/w isolator 88mmW x 88mmH x 59mmD
FPA-269/KEY Single key to suit FPA-269 and FPA-504 call points -
FPA-504 XP95® IP67 call point
 
112mmW x 112mmH x 68mmD

Cat No

Description

Dimensions

FPA-081/4
Protective cover to suit FPA-269 and FPA-504 call points
-

Cat No

Description

Dimensions

FPA-269
XP95® call point c/w isolator
88mmW x 88mmH x 59mmD

Cat No

Description

Dimensions

FPA-269/KEY
Single key to suit FPA-269 and FPA-504 call points
-

Cat No

Description

Dimensions

FPA-504
XP95® IP67 call point
 
112mmW x 112mmH x 68mmD
Cat No Description Dimensions Sound Output Flash Rate
FPA-295 XP95® ancillary loop-powered sounder base Ø115mm x 38mmH 85dba -
FPA-296 XP95® ancillary loop-powered sounder beacon base c/w isolator
 
Ø115mm x 38mmH
 
85dBA 60 per minute
FPA-298 XP95® integrated loop-powered sounder base c/w isolator
 
Ø115mm x 38mmH
 
91dBA -
FPA-337 XP95® CAT O. loop-powered sounder VAD base c/w isolator
 
Ø115mm x 38mmH
 
91dBA 30 per minute
FPA-338 XP95® CAT O. loop-powered VAD base c/w isolator
 
Ø115mm x 38mmH
 
- 30 per minute
FPA-492 XP95® loop-powered beacon base c/w isolator
 
Ø115mm x 38mmH
 
- 60 per minute
FPA-493 White locking cap to suit all XP95® base variants
 
Ø100mm x 13mmH
 
- -
FPA-494 Red locking cap to suit all XP95® base variants Ø100mm x 13mmH - -

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-295
XP95® ancillary loop-powered sounder base
Ø115mm x 38mmH
85dba
-

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-296
XP95® ancillary loop-powered sounder beacon base c/w isolator
 
Ø115mm x 38mmH
 
85dBA
60 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-298
XP95® integrated loop-powered sounder base c/w isolator
 
Ø115mm x 38mmH
 
91dBA
-

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-337
XP95® CAT O. loop-powered sounder VAD base c/w isolator
 
Ø115mm x 38mmH
 
91dBA
30 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-338
XP95® CAT O. loop-powered VAD base c/w isolator
 
Ø115mm x 38mmH
 
-
30 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-492
XP95® loop-powered beacon base c/w isolator
 
Ø115mm x 38mmH
 
-
60 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-493
White locking cap to suit all XP95® base variants
 
Ø100mm x 13mmH
 
-
-

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-494
Red locking cap to suit all XP95® base variants
Ø100mm x 13mmH
-
-
Cat No Description Dimensions Sound Output Flash Rate
FPA-274 XP95® intelligent red open-area sounder c/w isolator
 
Ø104mm x 97.5mmH
 
Low: 92dBA / High: 100dBA -
FPA-275 XP95® intelligent white open-area sounder c/w isolator Ø104mm x 97.5mmH
 
Low: 92dBA / High: 100dBA -
FPA-297 XP95® loop-powered beacon with clear lens and red flash (requires FPA-268 base)

 
Ø115mm x 38mmH
 
- 60 per minute
FPA-495 XP95® intelligent open-area sounder beacon with red lens c/w isolator
 
Ø104mm x 97.5mmH
 
Low: 92dBA / High: 100dBA 60 per minute
FPA-496 XP95® intelligent open-area sounder beacon with clear lens c/w isolator Ø104mm x 97.5mmH
 
Low: 92dBA / High: 100dBA 60 per minute
FPA-497 XP95® intelligent open-area beacon with red lens c/w isolator Ø104mm x 97.5mmH - 60 per minute
FPA-498 XP95® intelligent open-area beacon with clear lens c/w isolator Ø104mm x 97.5mmH - 60 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-274
XP95® intelligent red open-area sounder c/w isolator
 
Ø104mm x 97.5mmH
 
Low: 92dBA / High: 100dBA
-

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-275
XP95® intelligent white open-area sounder c/w isolator
Ø104mm x 97.5mmH
 
Low: 92dBA / High: 100dBA
-

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-297
XP95® loop-powered beacon with clear lens and red flash (requires FPA-268 base)

 
Ø115mm x 38mmH
 
-
60 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-495
XP95® intelligent open-area sounder beacon with red lens c/w isolator
 
Ø104mm x 97.5mmH
 
Low: 92dBA / High: 100dBA
60 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-496
XP95® intelligent open-area sounder beacon with clear lens c/w isolator
Ø104mm x 97.5mmH
 
Low: 92dBA / High: 100dBA
60 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-497
XP95® intelligent open-area beacon with red lens c/w isolator
Ø104mm x 97.5mmH
-
60 per minute

Cat No

Description

Dimensions

Sound Output

Flash Rate

FPA-498
XP95® intelligent open-area beacon with clear lens c/w isolator
Ø104mm x 97.5mmH
-
60 per minute
Cat No Description Dimensions Flash Rate
FPA-1090 XP95® red loop-powered VAD (15m) category C Ø100mm x 48mmH
 
0.5Hz
FPA-1091 XP95® red loop-powered VAD (8.5m) category C
 
Ø100mm x 50mmH
 
0.5Hz
FPA-1092 XP95® white loop-powered VAD (15m) category C
 
Ø100mm x 48mmH
 
0.5Hz
FPA-1093 XP95® white loop-powered VAD (8.5m) category C
 
Ø100mm x 50mmH
 
0.5Hz
FPA-1094 XP95® red loop-powered VAD (6m) category W
 
Ø100mm x 48mmH
 
0.5Hz
FPA-1095 XP95® white loop-powered VAD (6m) category W Ø100mm x 48mmH
 
0.5Hz

Cat No

Description

Dimensions

Flash Rate

FPA-1090
XP95® red loop-powered VAD (15m) category C
Ø100mm x 48mmH
 
0.5Hz

Cat No

Description

Dimensions

Flash Rate

FPA-1091
XP95® red loop-powered VAD (8.5m) category C
 
Ø100mm x 50mmH
 
0.5Hz

Cat No

Description

Dimensions

Flash Rate

FPA-1092
XP95® white loop-powered VAD (15m) category C
 
Ø100mm x 48mmH
 
0.5Hz

Cat No

Description

Dimensions

Flash Rate

FPA-1093
XP95® white loop-powered VAD (8.5m) category C
 
Ø100mm x 50mmH
 
0.5Hz

Cat No

Description

Dimensions

Flash Rate

FPA-1094
XP95® red loop-powered VAD (6m) category W
 
Ø100mm x 48mmH
 
0.5Hz

Cat No

Description

Dimensions

Flash Rate

FPA-1095
XP95® white loop-powered VAD (6m) category W
Ø100mm x 48mmH
 
0.5Hz
Cat No Description Suitable Use Dimensions
FPA-271 XP95® isolator
 
Detects short circuit faults on XP95® loops
 
Ø100mm x 35mmH
FPA-277 XP95® 24V intelligent input/output unit
 
To report fault, switch open and switch closed levels 150mmW x 90mmH x 48mmD
FPA-278 XP95® 230V intelligent mains switching input/output unit
 
To supervise one or more normally open switches 150mmW x 90mmH x 48mmD
FPA-279 XP95® sounder control unit c/w isolator and back box To control the operation of a zone of sounders 150mmW x 90mmH x 48mmD
 
FPA-281 XP95® zone monitor c/w isolator and back box
 
Controls the operation of up to 20 conventional detectors from a loop 150mmW x 90mmH x 48mmD
FPA-282 XP95® intelligent switch monitor Monitors one or more single pole Volt-free contacts 150mmW x 90mmH x 48mmD
FPA-284 XP95® mini switch monitor with isolator and interrupt Monitors equipment where a fast response is required 39mmW x 39mmH x 20mmD
FPA-561 XP95® 5A DIN-rail sounder controller Controls the operation of a zone of externally powered sounders 110mmW x 107mmH x 20mmD
FPA-567 XP95® DIN-rail input/output unit Provides supervision of one or more normally open volt free contacts connected to a single pair of cables and a set of changeover relay output contacts 33mmH x 102mmW x 33mmD
FPA-568 XP95® intelligent DIN-rail switch monitor
 
Monitors the state of one or more single pole, Volt-free contacts connected on a single pair of cables and reports the status 33mmH x 102mmW x 33mmD
 
FPA-569 XP95® DIN-rail mains switching input/output unit
 
Provides a mains-rated voltage-free, single pole change-over relay output and a monitored switch input 107mmW x 110mmH x 20mmD
FPA-573 XP95® DIN-rail zone monitor with isolator
 
Powers and controls a zone of up to 20 conventional detectors in an XP95 loop 107mmW x 110mmH x 20mmD
FPA-872 XP95® DIN-rail interface enclosure (4 unit capacity)
 
Houses up to 4 XP95® DIN-rail mounted interfaces 150mmH x 125mmW x 180mmD
FPA-901 XP95® DIN-rail interface enclosure (10 unit capacity)
 
Houses up to 10 XP95® DIN-rail mounted interfaces 150mmH x 180mmW x 225mmD

Cat No

Description

Suitable Use

Dimensions

FPA-271
XP95® isolator
 
Detects short circuit faults on XP95® loops
 
Ø100mm x 35mmH

Cat No

Description

Suitable Use

Dimensions

FPA-277
XP95® 24V intelligent input/output unit
 
To report fault, switch open and switch closed levels
150mmW x 90mmH x 48mmD

Cat No

Description

Suitable Use

Dimensions

FPA-278
XP95® 230V intelligent mains switching input/output unit
 
To supervise one or more normally open switches
150mmW x 90mmH x 48mmD

Cat No

Description

Suitable Use

Dimensions

FPA-279
XP95® sounder control unit c/w isolator and back box
To control the operation of a zone of sounders
150mmW x 90mmH x 48mmD
 

Cat No

Description

Suitable Use

Dimensions

FPA-281
XP95® zone monitor c/w isolator and back box
 
Controls the operation of up to 20 conventional detectors from a loop
150mmW x 90mmH x 48mmD

Cat No

Description

Suitable Use

Dimensions

FPA-282
XP95® intelligent switch monitor
Monitors one or more single pole Volt-free contacts
150mmW x 90mmH x 48mmD

Cat No

Description

Suitable Use

Dimensions

FPA-284
XP95® mini switch monitor with isolator and interrupt
Monitors equipment where a fast response is required
39mmW x 39mmH x 20mmD

Cat No

Description

Suitable Use

Dimensions

FPA-561
XP95® 5A DIN-rail sounder controller
Controls the operation of a zone of externally powered sounders
110mmW x 107mmH x 20mmD

Cat No

Description

Suitable Use

Dimensions

FPA-567
XP95® DIN-rail input/output unit
Provides supervision of one or more normally open volt free contacts connected to a single pair of cables and a set of changeover relay output contacts
33mmH x 102mmW x 33mmD

Cat No

Description

Suitable Use

Dimensions

FPA-568
XP95® intelligent DIN-rail switch monitor
 
Monitors the state of one or more single pole, Volt-free contacts connected on a single pair of cables and reports the status
33mmH x 102mmW x 33mmD
 

Cat No

Description

Suitable Use

Dimensions

FPA-569
XP95® DIN-rail mains switching input/output unit
 
Provides a mains-rated voltage-free, single pole change-over relay output and a monitored switch input
107mmW x 110mmH x 20mmD

Cat No

Description

Suitable Use

Dimensions

FPA-573
XP95® DIN-rail zone monitor with isolator
 
Powers and controls a zone of up to 20 conventional detectors in an XP95 loop
107mmW x 110mmH x 20mmD

Cat No

Description

Suitable Use

Dimensions

FPA-872
XP95® DIN-rail interface enclosure (4 unit capacity)
 
Houses up to 4 XP95® DIN-rail mounted interfaces
150mmH x 125mmW x 180mmD

Cat No

Description

Suitable Use

Dimensions

FPA-901
XP95® DIN-rail interface enclosure (10 unit capacity)
 
Houses up to 10 XP95® DIN-rail mounted interfaces
150mmH x 180mmW x 225mmD

Quick Enquiry

or call us on +44 (0) 1922 745024

0/250 Characters