Key Features

  • LPCB certified to the latest versions of EN54 Parts 2 and 4
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
  • 2, 4 or 8 zone circuits (dependent on model purchased)
  • 4 conventional sounder circuits
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU
  • Wide range of engineering functions including zone test, coincidence*, zone delay and non-latching zones*
  • 2 on-board relays (fire and fault)
  • 2 open-collector outputs (remote and reset)
  • ‘Class change’ and alert inputs
  • Installer friendly design accommodates easy first fix and straight forward maintenance
  • Attractive flush or surface mountable plastic lid and enclosure - no bezel required
  • Low 25mA quiescent current. Mains failed/internal sounder active, power supply and general fault lights lit
  • Multiple indicators
  • End of line units included (one per zone)
  • Ancillary system expansion connections provided for up to 8 two-wire repeaters (1 FPA -226 network driver card required per system) and optional relay card
  • Space for 2 x 12V 2.1Ah or 3.2Ah VRLA batteries
  • Standard panel versions have ancillary connections for system expansion, zone test and fault diagnostic facilities; standard panels also feature zone delay, non-latching zones and coincidence (double-knock) facilities
Features marked * fall outside the scope of EN54 part 2

Fire Alarm Panel

Fire Alarm Panel

Cat No Description Max Battery Type & Size
FP-038 2 zone conventional panel 2 x 3.2Ah (FPA-071)
FP-039 4 zone conventional panel 2 x 3.2Ah (FPA-071)
FP-040 8 zone conventional panel 2 x 3.2Ah (FPA-071)

Cat No

Description

Max Battery Type & Size

FP-038
2 zone conventional panel
2 x 3.2Ah (FPA-071)

Cat No

Description

Max Battery Type & Size

FP-039
4 zone conventional panel
2 x 3.2Ah (FPA-071)

Cat No

Description

Max Battery Type & Size

FP-040
8 zone conventional panel
2 x 3.2Ah (FPA-071)

Repeater Panel

Repeater Panel

Cat No Description Max Battery Type & Size
FPR-006 8 zone repeater panel 2 x 3.2Ah (FPA-071)

Cat No

Description

Max Battery Type & Size

FPR-006
8 zone repeater panel
2 x 3.2Ah (FPA-071)
Cat No Description
FPA-198 1 gang keyswitch auxiliary device isolator
FPA-199 24V 5A keyswitch with buzzer
FPA-226 Network driver card (1 required per system)
FPA-227 Relay output card (provides reset, fault aux fire and remote relay outputs)
FPA-228 Relay output card (as per FPA -227 plus 8 output per zone relays)
FPA-260 Spare red key for conventional/addressable fire alarm panels
FPA-996 4 zone monitored sounder extender 2 gang

Cat No

Description

FPA-198
1 gang keyswitch auxiliary device isolator

Cat No

Description

FPA-199
24V 5A keyswitch with buzzer

Cat No

Description

FPA-226
Network driver card (1 required per system)

Cat No

Description

FPA-227
Relay output card (provides reset, fault aux fire and remote relay outputs)

Cat No

Description

FPA-228
Relay output card (as per FPA -227 plus 8 output per zone relays)

Cat No

Description

FPA-260
Spare red key for conventional/addressable fire alarm panels

Cat No

Description

FPA-996
4 zone monitored sounder extender 2 gang
Dimensions
Width 380mm x Height 235mm x Depth 96mm

Weight
1.75Kg (without batteries)

Specification / Technical Information

  • Construction - RAL 7035 textured plastic lid and base
  • Ingress Rating - IP30
  • All fire alarm panels have 4 sounder circuits
  • Maximum of 8 repeater panels per system (network card required at main panel)
  • Repeater panel is only suitable for use with standard panels and cannot be used with economy panels
  • Batteries to be ordered separately