ZX Fire Alarm Panels

Easy to configure range of addressable fire panels compatible with many device manufacturers

ZX Fire Alarm Panels

Easy to configure range of addressable fire panels compatible with many device manufacturers

Key Features

  • All major device manufacturers devices supported
  • Optional, local or remote printers
  • Walk test facility
  • Provide up to 72hr stand-by (subject to verification)
  • Event logic – facilitates complex cross-panel programming
  • Auto-learn facility allows rapid and accurate commissioning of devices
  • Windows™ configuration tool allows off-site programming
  • Facility to print history and event logs
  • Shared Zone System - Each networked control panel shares information
  • Report & Control System - For multiple building sites where information is presented at the local and master panels only
  • A compliant fault tolerant network can be created using the additional, optional Hi-485 network card
  • 99 panel network allows systems in excess of 60,000 devices to be managed
  • 4 x 40 – Character LC D alphanumeric display with back-light
  • Up to 200 zone LEDs (by special request)
  • Up to 10 individual level 2 user access codes
  • Optional lockable glass door – provides added security/protection
  • Multi-protocol
  • Easy to install
  • Modular concept
  • Easy to maintain
  • Simple, robust design to EN54 Parts 2 & 4
  • Easy to expand
  • Intuitive to use
  • Easy to network
  • Easy to configure

Fire Alarm Panel

Fire Alarm Panel

Cat No Description Max Battery Type & Size
FP-030 1 loop ZX1Se addressable panel (no loop card) 2 x 12Ah (FPA-074)
FP-031 2 loop ZX2Se addressable panel (no loop cards) 2 x 12Ah (FPA-074)
FP-032 5 loop ZX5Se addressable panel (no loop cards) 2 x 24Ah (FPA-076)

Cat No

Description

Max Battery Type & Size

FP-030
1 loop ZX1Se addressable panel (no loop card)
2 x 12Ah (FPA-074)

Cat No

Description

Max Battery Type & Size

FP-031
2 loop ZX2Se addressable panel (no loop cards)
2 x 12Ah (FPA-074)

Cat No

Description

Max Battery Type & Size

FP-032
5 loop ZX5Se addressable panel (no loop cards)
2 x 24Ah (FPA-076)

Repeater Panel

Repeater Panel

Cat No Description Max Battery Type & Size
FPA-162 DXC/ZX active repeater panel N/A
FPA-163 DXC/ZX passive repeater panel N/A

Cat No

Description

Max Battery Type & Size

FPA-162
DXC/ZX active repeater panel
N/A

Cat No

Description

Max Battery Type & Size

FPA-163
DXC/ZX passive repeater panel
N/A
Cat No Description
FPA-149 RS232 communication module (used with FP-031 and FP-032 only)
FPA-150 RS485 communication module
FPA-153 Internal printer (used with FP-032 only)
FPA-161 Hi-485 communication module
FPA-188 Apollo XP95/Discovery loop card 460mA
FPA-190 Hochiki ESP loop card 460mA
FPA-191 System Sensor loop card 460mA
FPA-304 Short message communicator (for signalling alarm and other system conditions by sending a SMS text message to the user)
FPA-444 Interface lead for programming all Morley-IAS panels
FPA-447 Engineers software programming kit (inc. configuration tools)
FPA-448 Battery box to suit FP-030 and FP-031 panels
FPA-449 Battery box to suit FP-032 panel
FPA-453 Glass door kit to suit FP-030 and FP-031 panels
FPA-454 Glass door kit to suit FP-032 panel

Cat No

Description

FPA-149
RS232 communication module (used with FP-031 and FP-032 only)

Cat No

Description

FPA-150
RS485 communication module

Cat No

Description

FPA-153
Internal printer (used with FP-032 only)

Cat No

Description

FPA-161
Hi-485 communication module

Cat No

Description

FPA-188
Apollo XP95/Discovery loop card 460mA

Cat No

Description

FPA-190
Hochiki ESP loop card 460mA

Cat No

Description

FPA-191
System Sensor loop card 460mA

Cat No

Description

FPA-304
Short message communicator (for signalling alarm and other system conditions by sending a SMS text message to the user)

Cat No

Description

FPA-444
Interface lead for programming all Morley-IAS panels

Cat No

Description

FPA-447
Engineers software programming kit (inc. configuration tools)

Cat No

Description

FPA-448
Battery box to suit FP-030 and FP-031 panels

Cat No

Description

FPA-449
Battery box to suit FP-032 panel

Cat No

Description

FPA-453
Glass door kit to suit FP-030 and FP-031 panels

Cat No

Description

FPA-454
Glass door kit to suit FP-032 panel
FP-030 & FP-031:
Width 400mm x Height 400mm x Depth 135mm
(Weight 10Kg without batteries)

FP-032:
Width 500mm x Height 500mm x Depth 195mm
(Weight 20Kg without batteries)

Specification / Technical Information

  • Construction - Sheet steel with RAL 9002 grey white finish
  • Ingress Rating - IP30
  • Loop Capacity - 126 devices per loop Apollo, Hochiki and Nittan protocols
  • Loop Capacity - 198 devices per loop System Sensor and Morley protocols
  • Batteries to be ordered separately
  • 1 and 2 loop versions have 2 sounder outputs, 5 loop versions have 4 sounder outputs
  • Repeater panels require 24V power supply unit and RS485 communication card

Quick Enquiry

or call us on +44 (0) 1922 745024

0/250 Characters