Key Features

  • Designed to comply with EN54 Parts 2 and 4
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
  • Available with 2, 4 or 8 AlarmSense zone circuits (dependent on model purchased)
  • 4 conventional sounder circuits (for use with non-AlarmSense sounders)
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones
  • 2 on-board relays (fire and fault)
  • 2 open-collector outputs (remote and reset)
  • ‘Class change’ and alert inputs
  • Installer friendly design accommodates easy first fix and straight forward maintenance
  • Low quiescent current
  • Multiple indicators
  • End of line units included (one per zone)
  • Ancillary system expansion connections provided for up to 8 two-wire repeaters (1 FPA -226 network driver card required per system) and optional relay card
  • Space for 2 x 12V 2.1Ah or 3.2Ah VRLA batteries
  • Attractive flush or surface mountable plastic lid and enclosure (no bezel required)
  • Third party LPCB tested

Fire Alarm Panel

Fire Alarm Panel

Cat No Description Max Battery Type & Size
FP-041 2 zone two-wire panel 2 x 3.2Ah (FPA-071)
FP-042 4 zone two-wire panel 2 x 3.2Ah (FPA-071)
FP-043 8 zone two-wire panel 2 x 3.2Ah (FPA-071)

Cat No

Description

Max Battery Type & Size

FP-041
2 zone two-wire panel
2 x 3.2Ah (FPA-071)

Cat No

Description

Max Battery Type & Size

FP-042
4 zone two-wire panel
2 x 3.2Ah (FPA-071)

Cat No

Description

Max Battery Type & Size

FP-043
8 zone two-wire panel
2 x 3.2Ah (FPA-071)

Repeater Panel

Repeater Panel

Cat No Description Max Battery Type & Size
FPR-006 8 zone repeater panel 2 x 3.2Ah (FPA-071)

Cat No

Description

Max Battery Type & Size

FPR-006
8 zone repeater panel
2 x 3.2Ah (FPA-071)
Cat No Description
FPA-198 1 Gang Keyswitch Auxiliary Device Isolator
FPA-199 24V 5A Keyswitch with Buzzer
FPA-226 Network Driver Card (1 Required Per System)
FPA-227 Relay Output Card (Provides Reset, Fault Aux Fire and Remote Relay Outputs)
FPA-228 Relay Output Card (as Per FPA-227 Plus 8 Output Per Zone Relays)
FPA-260 Spare Red Key for CFP/XFP Fire Alarm Panels
FPA-996 4 Zone Monitored Sounder Extender 2 Gang

Cat No

Description

FPA-198
1 Gang Keyswitch Auxiliary Device Isolator

Cat No

Description

FPA-199
24V 5A Keyswitch with Buzzer

Cat No

Description

FPA-226
Network Driver Card (1 Required Per System)

Cat No

Description

FPA-227
Relay Output Card (Provides Reset, Fault Aux Fire and Remote Relay Outputs)

Cat No

Description

FPA-228
Relay Output Card (as Per FPA-227 Plus 8 Output Per Zone Relays)

Cat No

Description

FPA-260
Spare Red Key for CFP/XFP Fire Alarm Panels

Cat No

Description

FPA-996
4 Zone Monitored Sounder Extender 2 Gang
Dimensions
Width 380mm x Height 235mm x Depth 96mm

Weight
1.75Kg (without batteries)

Specification / Technical Information

  • Construction - RAL 7035 textured plastic lid and base
  • Ingress Rating - IP30
  • All fire alarm panels have 4 sounder circuits
  • Batteries to be ordered separately
  • Maximum of 8 repeater panels per system (network card required at main panel)
  • Repeater panel is only suitable for use with standard panels and cannot be used with economy panels